ADC H2TU-C-388 Network Card User Manual


 
152-388-100-02, Issue 2 Provisioning
H2TU-C-388 List 1 June 6, 2000 15
Configuring the System
The Config menu (Figure 6) allows you to make the following types of system configuration changes:
Standard options (Figure 7 on page 16)
ADC options (Figure 8 on page 16)
Date and time (see Setting Date and Time on page 13)
Master clear (see Clearing the History, Alarm, and Event Log Screens on page 21)
Reset to factory default configuration (Figure 9 on page 20)
Figure 6. Configuration Menu
Making Changes to Standard and ADC Options
Figure 7 and Figure 8 on page 16 show the Standard and ADC configuration options. Standard options are those
that are supported by HiGain units when connected to units from other vendors. ADC options are an extended set
of options that are only available when using HiGain units exclusively. For a description of each option and a list
of possible option settings, refer to Table 5 on page 17 and Table 6 on page 18. To make changes to these options:
1 Type to select the Config menu.
2 Use the and arrow keys to select Standard Options or ADC Options, and press .
3 Use the arrow keys to select an option.
4 Press the to cycle through the available settings for that option.
5 Press to activate your choice.
Monitor Performance Event Log Config Inventory Rlogon Help
+----------------------+
|
Standard Options -> |
| PairGain Options -> |
| Date and Time -> |
| Master Clear |
| Set Factory Defaults |
+----------------------+
ID: xxxx--xxxx--xxxx--xxxx 04/15/00 12:30:01 H2TU-C S
y
stem: OK
C
ENTER
SPACEBAR
ENTER