Chapter 2. Installation and Operation
2-12 MX2800 User Manual 61200659L1-1
The MX2800 STS-1
M
AIN
M
ENU
consists of the following sections:
Status
Provides information on the current state of the STS-1, power
supplies, system, and VT/Port lines. For more detailed information,
see Chapter 4, Status.
Statistics
Provides detailed statistical information (both current and
historical) for the STS-1, VT, and Port lines. For more detailed
information, see Chapter 5, Statistics.
Configuration
Sets STS-1 network, VT/Port, and system management parameters.
For more detailed information, see Chapter 3, Configuration.
Diagnostics
Performs loopback tests over the STS-1, VT/Port lines. For more
detailed information, see Chapter 6, Diagnostics.
Logout
The
L
OGOUT
selection ends the terminal session and logs out of the
system. Password entry is required before a new session can begin.
The unit will also logout of a terminal session automatically if the
session remains inactive for a certain period of time. For more
information, see Terminal Timeout on page 3-35.
ACO Buttons
The
ACO
(alarm cut off) buttons allow you to turn off an active
audible alarm. The buttons are recessed, so you must use a pen or
other pointed instrument to press them. Once you have used an
ACO
end the terminal
session
Ctrl-C
refresh the display
Ctrl-R
If you want to... Press...