ADTRAN 4200659L6 Switch User Manual


 
Chapter 3. Configuration
3-34 MX2800 STS-1 User Manual 61200659L1-1
MIB II Standard Alarm Traps
Read Community Name
Enter the authentication strings used for SNMP management.
Match the MX2800 STS-1 to the SNMP manager for read
privileges.
Write Community Name
Enter the authentication strings used for SNMP management.
Match the MX2800 STS-1 to the SNMP manager for write
privileges.
Trap Community Name
Enter the identification string used for trap management. This string
accompanies all traps transmitted by the MX2800 STS-1.
Bat. Backup
Active
Battery charger has lost its AC source and is
now running off the battery backup
Battery Low the battery backup has reached a critical energy
point at which it may be unable to supply the unit
with sufficient power to maintain operation
Temperature
High
the power supply card is getting too hot
Temperature
Crit
the power supply card temperature is so high
that it may suffer damage
Trap If enabled, the unit issues a trap when...
Cold Start the unit is first powered up
Link Up the STS-1 is up with no alarms
Link Down the STS-1 is in alarm
Auth. Failure an attempt has been made by an unauthorized
user to access the unit
Trap If enabled, the unit issues a trap when...