AEG ARE I2 Computer Hardware User Manual


 
Manual
Page 11 / 33- Revision 01
ARE I2 / RS 232 – Installation Guide
AEG
Identifikationssysteme GmbH
Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
e-mail: info@AEGID.de
4.3.5 Final Assembly of the Cable Pipe
Pull by and by all the cable back, until the isolation of the cables are near to beginning of
the cable pipes.
Fasten nuts (5) of the cable pipes with the right tool (17mm).
Do this carefully, to ensure the tightness of the protection class of IP 65..
Plug the finished assembled MINI-COMBICON-Connector to the SAB Cab. Take care of
the correct coding ((7) in Figure 4-2) of the connectors.
4.3.6 Plug in of the SAB Cab
Attention:
Before plugging the SAB Cab to the connectors of the reader, make sure that the
grounding of the device is well done. Otherwise the electronic may be destroyed by elec-
trostatic discharge (ESD).
Figure 4-3: Plug on the SAB Cab
Put on the sealing 2 to the SAB Cab (A).
Plug in the SAB Cab to the connector at the bottom of the reader device (B).
There is only one way to plug in the SAB Cab to the connector rim of the reader.
Fasten the SAB Cab with the help of the screws.
1
2
A
B