AEG ARE I2 Computer Hardware User Manual


 
Manual
Page 22 / 33- Revision 01
ARE I2 / RS 232 – Installation Guide
AEG
Identifikationssysteme GmbH
Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
e-mail: info@AEGID.de
Figure 7.1.2 : Software triggered reading operation with TOR>0
Please note: The TOR parameter is only active, if the GT-Command is applied. Within the
time span defined by the value of TOR no NoRead will be output on the interface!
7.1.1 Settings of the Reader / Most Used Parameters
The default operation mode is changed by sending a software command to the reader.
In combination with an R / W transponder, the serial number of the transponder device is read
out only.
MD 2 - triggerd by an software command
most used parameters.
CID 0 - no suppression of repeatedly read Ids
CN 0 - no suppression of NoReads
NID 1 failure protection.; selection guide 2 out 2 transponder codes
TOR XYZ maximum reading time after the standard read command
is applied to the reader. The chosen value must match the
timing demands of the production process.
TOR 5 Default value
exciter
processor
interface
TOR
GT
reading process
NoRead
reading cycle reading cycle reading cycle