Agilent Technologies 8510C Network Router User Manual


 
4
Agilent 85108A pulsed-RF network analyzer system
(2 GHz to 20 GHz)
Based on an 8510C with Option 008, this system
provides the capability to measure the amplitude
and phase response of a device or component
being driven with a pulsed-RF input signal. The
instruments are integrated in a 1600 mm system
rack. It is fully tested and a complete system verifi-
cation is performed prior to shipment from the
factory. Installation is included at no additional
charge.
System components include:
8510C network analyzer with Option 008
(pulsed-RF measurement capability)
85110A test set
1600 mm rack
83622B synthesizer with Options 001/004/008
83623L synthesizer with Options 004/008
Calibration kits and test port cables in the
appropriate connector interface are not
included and must be ordered separately.
Frequency range (select one)
85108A-STD 2 - 20 GHz
85108A-E63 500 MHz - 20 GHz
85108A-F61 2 - 50 GHz with front panel connectors
85108A-F62 45 MHz - 50 GHz
Features
8510C-010 Add time domain
Voltage options
85108A-115 110/120 V line voltage operation
85108A-230 220/240 V line voltage operation
Extended service options are available.
Agilent 85108L pulsed-RF network analyzer system
(45 MHz to 2 GHz)
Based on an 8510C with Option 008, this system
provides the capability to measure the amplitude
and phase response of a device or component
being driven with a pulsed-RF input signal. The
instruments are integrated in a 1600 mm system
rack, the system is fully tested, and a complete sys-
tem verification is performed prior to shipment
from the factory. Installation is included at no
additional charge.
System components include:
8510C network analyzer with Option 008
(pulsed-RF measurement capability)
85110L test set
1600 mm rack
83620B synthesizer with Options
001/004/008/H80
83620B synthesizer with Options 004/008/H80
Calibration kits and test port cables in the
appropriate connector interface are not
included and must be ordered separately.
Features
8510C-010 Add time domain
Voltage options
85108L-115 110/120 V line voltage operation
85108L-230 220/240 V line voltage operation
Extended service options are available.
Agilent 85122A high frequency device modeling system
(45 MHz to 20 GHz)
When combined with the 85190 series high
frequency IC-CAP software, along with Cascade
probes or ICM fixtures, the 85122A can be used to
model BJT, FET, MOS, and diode devices. All
instruments are integrated in a 1600 mm system
rack prior to shipment from the factory.
Installation is included at no additional charge.
System components include:
8510C network analyzer
8514B test set
83621B synthesizer
11612A Option K10/K20 force/sense bias networks
4156C DC source/monitor
85131F cable set
1600 mm rack
Probes, fixtures, calibration kits, 85190 series
software, and workstation must be ordered
separately.
Option 230 provides system cabinet set up for
220/240 V operation
Custom configurations available to meet other
frequency coverage and power requirements.