If the "Ethernet" selection appears in the Communications menu,
then go to step 5.
If "Ethernet" does not appear in the Communications menu, perform
the following steps.
a
Remove power from the HP 16500B, disconnect the power cable, then
remove the top cover.
b
Remove and inspect the interface module cable for signs of damage.
If the cable appears defective, replace it.
c
Ensure that the cable is connected according to the installation
procedures and that all cables are properly seated. For installation
procedures, refer to chapter 2, "Installing the Interface Module."
d
Install the top cover of the HP 16500B mainframe, connect the power
cable, and reapply power.
If Ethernet still does not appear, then suspect a defective CPU board.
Refer to the
HP 16500B/16501A Service Guide
for infomation on
testing and replacing the CPU baord.
5
Touch Configuration, then touch Test. When the test menu appears,
touch the blue field to load the performance verification test system.
Servicing the Interface Module
Verify the Interface Module Performance
3-4