Special Menu
Fine tunes and sets the special functions manuall
y
:
ID-NUMBER 1~99 )、INSTANT-ON DEGAUSS
AUTO-SAVING AUTO DEGAUSS AUTO SHIFT
OSD BACKGROUNDOSD CONTRASTAND OSD H
V-POSITIONMOIRE KEY LOCKPASSWORD.
a. ID Number Through DM RS232 V0.9 (Serial Transmission
Communication interface) to remote control the
device. To identify the monitor, you must to set an ID
number (ID=1~99) to each of the monitor under DM
RS232 V0.9 Control page.
1. Select the ID number (1~99) by  tab.
2. After you set the ID, choose high/light to identify the
monitor with has been set with a valid number. The
monitor will correspond with the current status, and this
could control the OSD function directly.
b. Instant-On
EnableDisable the INSTANT-ON. Set the INSTANT–
ON YES, the Monitor will start up immediately while the
Power switch on, and the green LED is lit on. The monitor
will stay in the saving mode till the power be turn-on again
while the INSTANT-ON is switch off, and the red LED is lit
on.
c. Auto Saving The power will shut down automatically and be in the
power-saving status while the Auto Saving switch on.
e. Degauss
EnableDisable the AUTO DEGAUSS.
The AUTO DEGAUSS will be executed automatically by
every 24 hours since switch on the function.
f. Auto Shift
A
ctive AUTO SHIFT to protect the screen from result in
the image-remain. The picture will be auto-shift once
every 6 hours.
21
g. Moiré For some modes, it is better to switch the moiré off to get
better video performance, and this option is provided
when Moiré is ON, adjust MOIRE pops out, and adjust
moiré by using +∕-key. In TV
A
V mode, moiré can’t
be adjusted.
h. Key Lock
EnableDisable the front panel function operation.
i. Password To release the disable front panel function operation by
set the password.
j. OSD
Background
Switch the OSD background ON or OFF to adapt to
different software background of the PC.