Allied Telesis AT-8000S Switch User Manual


 
AT-S94 Version 3.0.0.45 Software Release Notes
PN 613-001777 Rev A 5 Allied Telesis, Inc.
8. Verify that your switches are running the correct boot loader by using the following command:
show version
With information displayed from the “show version” command, copy the boot version number
exactly as shown. Using this number as the password, extract the ats94-30045.ros software
upgrade file from the ats94-30045.zip file.
9. Use one of the following commands depending on your configuration:
Note
You must substitute the IP address of your local TFTP server.
For a stand alone switch -
Copy tftp://192.168.1.10/ats94-30045.ros image
For a stack configuration -
Copy tftp://192.168.1.10/ats94-30045.ros unit://*/image
10. Before rebooting the stand alone switch or stack, you must change the active image,
including each slave switch in the stack. To check the active image for each switch use the
following command.
Show bootvar
The resulting display will tell you which image is active on each switch. Depending on your
configuration, you can now issue one of the following commands, substituting x and y from
the Show bootvar command:
For a stand alone switch -
Boot sys image-y
For each switch in a stack -
Boot sys unit x image-y
Switch the active image for next reboot.
11. Reboot the device with the command:
reload
This command will cause the switch to reboot. By the end of the reboot process, Version
3.0.0.45 software will be running.
Software Installed with Incorrect Bootloader
If you accidentally install the Version 3.0.0.45 software on a switch without the latest boot loader,
the switch will fail to boot properly. To recover from this situation, you must obtain a previous
version of software (V3.0.0.35 or V3.0.0.38) from our ATI web site and perform the following
procedure to install this software using the XMODEM protocol:
1. Set up a console port connection.