Allied Telesis AT-8000S Switch User Manual


 
AT-S94 Version 3.0.0.45 Software Release Notes
PN 613-001777 Rev A 8 Allied Telesis, Inc.
EWS - User can not add a VLAN via GUI interface if the VLAN ID starts with 5,6,7,8,9 (CQ ID
115354)
SNMP - Added support for SNMP trap when master stack unit is down (CQ ID 117040)
Version 3.0.0.33
When the master was lost (powered down) the SFP port(s) on backup changed to DOWN –
link changed to half duplex and remained down. This issue has been resolved.
Version 3.0.0.32
Unregistered Multicast - when a user configures unregistered multicast to be filtered then
broadcast packets were mistakenly also identified as unregistered multicast and therefore
were also filtered (CQ ID 112258)
DVA - When the bridge address table is full and unregistered multicast are set to be filtered
the device fails with fatal error (CQ ID 112338)
The MAC groups mapping is not working for IGMP packets (CQ ID 89459)
Guest VLAN should be accessible only after timeout/fail authentication (CQ ID 68048)
Dynamic VLAN assignment need to allow support for tag<>0 in attribute [81] Tunnel-Private-
Group-Id (CQ ID 103461)
Command qos wrr-queue threshold should be removed from the CLI Guide (CQ ID 104433)
Traffic shaping should not be applied if port is in half duplex (CQ ID 106326)
FE/GE ports, Storm control range of supported values is incorrect in the CLI guide (CQ ID
108733)
In order to get a clean, functional compile using Castlerock SNMP need to make a few
changes to the MIB files (CQ ID 109360)
SYSLOG - on EWS system/event log modify tab “minimum severity” should be changed
to”facility” (CQ ID 111154)
SNMPv1/2 - MIB file: Some mib files compile error (CQ ID 111073)
SNTP - After enabling SNTP via EWS, the SNTP Unicast Clients and Unicast Clients polling
is still not enabled (CQ ID 110764)
EWS - At standalone DUT, EWS will display non-existed port g3,g4 (CQ ID 110769)
Diagnostic LED - The Diagnostic LED Indications in Table 7 on Page 20 of the AT-8000S
Installation Guide should read as follows:
LED Description LED Indication Description
Diag
Green System Diagnostics in progress.
Off System Diagnostics successfully completed.