American Power Conversion S15BLK Power Supply User Manual


 
1-11
BUILDING WIRING FAULT Indicator
If this indicator is lit, then one of three wiring problems exists in the
building wiring circuit:
Missing ground
Overloaded neutral
Reversed polarity
Contact a licensed electrician to resolve the problem.
Input Power Connector
Connect one end of the supplied AC power cord to the S10 or S15 AC
Input Power Connector. Connect the other end of the power cord to the
AC utility power source (120 Vac, 15A, 50 to 60 Hz).
DC TRIGGER Jacks
Provides for connection of a component acting as a DC trigger, which
controls turn on/off, as well as sequencing of the DELAYED1 and 2
outlet banks. The S10 and S15 also allows that DC signal to pass through
to another connected component.
Caution: When connecting to the DC Trigger jacks, connect the source of
the DC Trigger to the IN jack. The OUT jack should be used
only as a pass-through. The DC Trigger signal can be short
circuited if the input and output cables are reversed. The
maximum input voltage for the DC Trigger is 30VDC. Do not
apply an AC voltage to the DC Trigger jacks. Failure to comply
with this statement may result in equipment damage.
ETHERNET Surge Protected Jacks
The S15 protects a device connected to a home network from surges
traveling over Ethernet data lines. Connect the supplied RJ45 cable from
the wall jack (source) to the connector marked IN. Connect another
network cable from the connector marked OUT to the network equipment
to be protected.
6
!
7
8
!
9