2-18
GO TO BATTERY IF > XXXV Setting – This function allows you to set a high
voltage threshold for the unit, which forces it to switch to power from the internal
battery pack once the threshold has been reached. The settings range is from 134 to
144 volts, as shown in Figure 25.
Figure 25. GO TO BATTERY IF > XXXV Setting Screen
GO TO BATTERY IF < XXXV Setting (not shown) – This lets you set a low
voltage threshold for the unit, which will force it to switch to power from the internal
battery pack when the threshold is reached. Settings range from 90 to 100 volts.
OUTLET DELAY1 and OUTLET DELAY2 Setting (not shown) screens – let you
set a defined time delay (0 to 10 seconds) for when the unit provides power to the
rear panel outlet marked Delayed1 (TUNER/AUX) or Delayed2 (SUBWOOFER
and/or AMPLIFIER). By setting this delay it prevents power on or power off
glitches from affecting other equipment connected to the unit. Outlet Delay1 is
shown in Figure 26; the Outlet Delay2 screen is not shown.
Figure 26. Outlet Delay1 Setting Screen