AMT Datasouth 5106 Network Router User Manual


 
23
NAME
Media Gap (Label Gap)
Black Line
Ribbon
Presentation (Strip)
Head-Up
ADJUSTMENT PROCEDURE (Message on Display)
By volume B in media compartment.
Sensitivity range (1
st
).
With Gap, 70% or more.
With media (label), 35% or less
SEE ABOVE NOTE BEFORE MAKING ADJUSTMENT
By volume B in the media compartment.
Sensitivity range (2
nd
)
When black paper or color except black, 70% or more
When black line, 35% or less
By VR1 on TPB-2170
Sensitivity range (Rib)
With no ribbon, 70% or more
With ribbon, 25% or less
By VR2 on TPB-2170.
Sensitivity range (Pre)
When media (label), 75% or more
When no media (label), 25% or less
No volume for sensitivity adjustment.