Terminal (Program Port/Telnet) Commands
101
NI Series WebConsole & Programming Guide
Terminal Commands (Cont.)
Command Description
SET TELNET PORT Sets the Master’s IP port listened to for Telnet connections.
Note: The Master must be rebooted to enable new settings.
Example:
>SET TELNET PORT
Current telnet port number = 23
Enter new telnet port number (Usually 23)(0=disable Telnet):
Once you enter a value and press the ENTER key, you get the follow-
ing message:
Setting telnet port number to 23
New telnet port number set, reboot the Master for the
change to take affect.
SET THRESHOLD Sets the Master's internal message thresholds.
This command will set the thresholds of when particular tasks are
pended. The threshold is the number of messages queued before a
task is pended.
Use extreme caution when adjusting these values.
Note: The Master must be rebooted to enable new settings.
Example:
>SET THRESHOLD
-- This will set the thresholds of when particular tasks are
pended. The threshold is the number of messages queued before a task
is pended.--
--Use extreme caution when adjusting these values.--
Current Interpreter Threshold = 2000
Enter new Interpreter Threshold (Between 1 and 2000)(Default=10):
Once you enter a value and press the ENTER key, you get the follow-
ing message:
Current Lontalk Threshold = 50
Enter new Lontalk Threshold (Between 1 and 2000) (Default=50):50
Current IP Threshold = 600
Enter new IP Threshold (Between 1 and 2000) (Default=200): 600
Setting Thresholds to: Interpreter 2000
Lontalk 50
IP 600
New thresholds set, reboot the Master for the changes to
take affect.
SET TIME Sets the current time.
When the time is set on the Master, the new time will be reflected on
all devices in the system that have clocks (i.e. touch panels). By the
same token, if you set the time on any system device, the new time
will be reflected on the system’s Master, and on all connected devices.
Note: This will not update clocks on devices connected to another
Master (in Master-to-Master systems).
Example:
>SET TIME
Enter Date: (hh:mm:ss) ->
SET TIMELINE LOOPCNT Sets the Master's timeline/event max loopcount.