Asante Technologies 100 Switch User Manual


 
Setting Alarms
Page 3-25
Field Description Action
Index Displays the number of the
alarm entry.
This field is read-only; it
cannot be edited.
Status The status of the alarm
entry.
Select valid to add an
alarm or invalid to delete
the alarm.
Target Domain The portion of the device
for which the alarm is to
be set.
Select port, group, or
segment0 (device) from
the drop-down menu.
Target Group The number of the group
for which the alarm is to
be set.
Only enter a group num-
ber if group was selected
as the Target Domain.
Target Port The number of the port for
which the alarm is to be
set.
Only enter a port number
if port was selected as the
Target Domain.
Subject The counter to be polled
for the alarm.
Select a counter from the
drop-down menu.
See “Subject” on page 4-
14 for a description of each
counter.
Sample Type The unit of measure for
the alarm.
This field cannot be edited;
it is always set to event-
persecond.
Startup Event Determines when the
alarm is to be triggered.
Select rising, falling, or ris-
ingANDfalling from the
drop-down menu.
See “Startup Event” on
page 4-15 for a descrip-
tion of each event.
Threshold
Value
The value that triggers the
alarm.
Enter an integer.
Detected Value Displays the last measure-
ment made.
This field is read-only; it
cannot be edited.
Rising Event The response to occur for
a triggered rising event.
Select a response from the
drop-down menu.
See “Rising Event” on
page 4-15 for a descrip-
tion of each response.
Falling Event The response to occur for
a triggered falling event.
Select a response from the
drop-down menu.
See “Falling Event” on
page 4-15 for a descrip-
tion of each response.
100NMM PM book Page 25 Wednesday, August 27, 1997 12:40 PM