Field Description
Subject Configurable field; determines the counter to be
polled.
readableframes — the total number of good or
readable frames (frames without error).
frametoolong — the number of frames that
were longer than 1,518 bytes.
runts — the number of frames that were
shorter than 64 bytes.
alignmenterrors — the number of frames that
were an integral number of octets in length
and did not pass the FCS check.
fcserrors — the number of frames that failed
Cyclic Redundancy Check (CRC).
dataratemismatch — the number of errors
where the incoming data rate is not within the
tolerance level of 10Mhz (+ or - 0.01%).
shortevents — the number of data bursts,
where data is less than 10 bytes in length.
collisions — the total number of collisions.
latecollisions — the number of collisions that
occurred after the 64-byte collision window.
autopartitions — the number of times the port
was automatically partitioned in response to
31 or more continuous collisions.
badframes — the number of invalid frames
(including toolong, runts, misaligned, or bad
FCS).
Sample Type Read-only field; sets a unit of measure for the alarm.
Note:
This field is always set to eventpersecond and
cannot be modified.