5-24 Chapter 5: RAID conguration
5.2.6 Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected logical
drive. The utility can automatically detect and/or detect and correct any differences
in data redundancy depending on the selected option in the
Objects
>
Adapter
menu.
The
Check Consistency
command is available only for logical drives included
in a RAID 1 set.
Using the Check Consistency
To check data consistency using the
Check Consistency
command:
1. From the
Management Menu
, select
Check Consistency
, then press
<Enter>.
2. The screen displays the available RAID set(s) and prompts you to select the
logical drive to check. Press the <Spacebar> to select the logical drive from
the
Logical Drive
selection, then press <F10>.
LSI Logic Software RAID Conguration Utility Ver A.51 Aug 13, 2007
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
CC Of VD(s)
LSI Logic Software RAID Conguration Utility Ver A.51 Aug 13, 2007
SPACE-(De)Select, F10-Check Consistency
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
Select VD
Logical Drive(s) Congured
LD RAID Size #Stripes StripSz Status
0 10 154494MB 4 64 KB ONLINE
Logical Drives
Loical Drive 0