Asus DSEB-D16/SAS Computer Hardware User Manual


 
ASUS DSEB-D16 Series 5-29
5.2.9 Enabling the WriteCache
You may enable the RAID controller’s WriteCache option to improve the data
transmission performance.
When you enable
WriteCache
, you may lose data when a power interruption
occurs while transmitting or exchanging data among the drives.
To enable WriteCache:
1. From the
Management Menu
, select
Objects
>
Adapter
, then press <Enter>
to display the adapter properties.
2. Select
WriteCache
, then press <Enter> to turn the option
On
(enabled).
3. When nished, press any key to continue.
LSI Logic Software RAID Conguration Utility Ver A.51 Aug 13, 2007
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
Disk Write Cache - Off(Write Through) or On(Write Back)
Objects
Adapter
Virtual Drive
Physical Drive
Adapter 0
Rebuild Rate = 30
Chk Const Rate = 30
FGI Rate = 30
BGI Rate = 30
Disk WC = Off
Read Ahead = On
Bios State = Enable
Stop On Error = No
Fast Init = Enable
Auto Rebuild = On
Auto Resume = Enable
Disk Coercion = 1GB
Factory Default