Asus M2A-MVP Computer Hardware User Manual


 
ASUS M2A-MVP 2-45
Creating a JBOD conguration
To create a JBOD set:
1. From the ULI RAID BIOS Setup utility menu, move the cursor to Create
JBOD for integrated capacity then press <Enter>.
2. Use the up or down arrow keys to select a drive then press <Space> or
<Enter>. The striped mark “J” appears before a selected drive.
3. Repeat step 2 to select the second drive.
4. The utility prompts the following warning message:
Data on RAID drives will be deleted (Y/N)?
Press <Y> to continue or press <N> to return to the menu.
Creating a RAID 0+1 conguration
To create a RAID 0+1 set:
1. From the ULI RAID BIOS Setup utility menu, move the cursor to Create
RAID 0+1 Striping, Mirroring then press <Enter>.
2. The utility prompts the following warning message:
Data on rst 4 drives will be deleted (Y/N)?
Press <Y> to continue or press <N> to return to the menu.
3. Key in a RAID name with a maximum of eight (8) alphanumeric characters
then press <Enter>. Do not use special characters or symbols.
4. The utility displays the RAID Array settings at the bottom of the screen.
Drive Model Mode Capacity RAID Array/Type
Channel 0 Master: XXXXXXXXXXX SATA 2 XXXXX MB RAID A/RAID0+1
Channel 1 Master: XXXXXXXXXXX SATA 2 XXXXX MB RAID A/RAID0+1
Channel 2 Master: XXXXXXXXXXX SATA 2 XXXXX MB RAID A/RAID0+1
Channel 3 Master: XXXXXXXXXXX SATA 2 XXXXX MB RAID A/RAID0+1
Capacity RAID Type Stripe Size RAID Name
RAID Array A : XXXXX MB 0+1 X4 RAID01
RAID Array B :
RAID Array C :