3-18 Chapter 3: Software support
Repairing a Mirror conict
A Mirror conict occurs when one or both disks in a RAID 1 (Mirror)
conguration are unplugged from the system, then plugged in again. Since
both disks contain exactly the same data, the system will be unable to
determine which of the two is the source drive. This option allows you to
set the source drive and rebuild the Mirror drive according to the contents
of the source drive.
To repair a Mirror conict:
1. In the main JMB363 RAID BIOS menu, highlight Repair Mirror Conict
using the up/down arrow key then press <Enter>.
2. Use the space bar to select the HDD that you want to set as source
drive.
The selected HDD shows a
sign before it.
3. Using the <TAB>, move to the RAID Disk Drive List menu and highlight
the RAID set that you want to rebuild. Press <Del> to begin rebuilding
the Mirror conguration.
[Main Menu]
Create RAID Disk Drive
Delete RAID Disk Drive
Revert HDD to Non-RAID
RepairMirrorConict
Save and Exit Setup
Exit Without Saving
JMicron Technology Corp. PCI-to-SATA II/IDE RAID Controller BIOS v0.97
[Hard Disk Drive List]
Model Name Capacity Type/Status
HDD0: HDS722516VLSA80 164 GB RAID Inside
HDD1: HDS722516DLA380 164 GB RAID Inside
[RAID Disk Drive List]
Model Name RAID Level Capacity Status Members(HDDx)
RDD0: JRAID 1-Mirror XXX GB Rebuild 01
[Main Menu]
Create RAID Disk Drive
Delete RAID Disk Drive
Revert HDD to Non-RAID
RepairMirrorConict
Save and Exit Setup
Exit Without Saving
Rebuilding... 01%, please wait...