5-36 Chapter 5: RAID conguration
3. The following screen appears. Select a channel and press <Enter> to enter
the setup.
The numbers of the channel depend on the controller.
5.4.1 RAID 1 volume
The RAID 1 feature supports simultaneous mirrored volumes with two disks.
The RAID 1 feature supports hot swap capability, so when a disk in an RAID
1 volume fails, you can easily restore the volume, and the swapped disk is
automatically re-mirrored.
To create a RAID 1 volume:
1. Turn on the system after installing all SAS hard disk drives.
2. During POST, press <Ctrl+C> to enter the SAS conguration utility.
LSI Corporation MPT SAS2 BIOS
MPT2BIOS-7.05.01.00 (2010.04.30)
Copyright 2000-2010 LSI Corporation.
Press Ctrl-C to start LSI Corp Conguration Utility...
To avoid data loss, do not turn off the system when rebuilding.
Esc = Exit Menu F1/Shift+1 = Help
Alt+N = Global Properties -/+ = Alter Boot Order Ins/Del = Alter Boot List
LSI Corp Cong Utility v7.07.00.00 (2010.04.30)
Adapter List Global Properties
Adapter PCI PCI PCI PCI FW Revision Status Boot
BUS Dev Fnc Slot Order
SAS 2008 01 00 00 00 8.00.00.00-IR Enabled 0