User Manual Model 676 LOKPRINT® Electrical Trouble Shooting •
••
• 41
Problem Probable Cause Corrective Action
Front panel does not
complete diagnostics test 2.
1) One or more PC board(s)
unplugged from the Mother
Board.
1) Power off and remove the power cord from the
AC entry. Remove the back cover and reseat the
offending board.
Machine does not receive
batches.
1) Serial communications cable
loose or unconnected.
1) Check and secure both ends of the serial cable
with the thumbscrews.
2) Machine not powered on or has
not completed diagnostics tests.
2) Power machine on and wait until machine
displays "Ready for batches". Re-download
data.
3) Data sent to wrong printer. 3) In PCMate change to the printer the data is
intended to be sent.
4) Configuration incorrect in
PCMate.
4) Re configure PCMate for AVERY DENNISON
PCL printer as per your PCMate manual.
5) Faulty Thermal Control Board. 5) Replace Thermal Control Board.
6) Jumpers not configured
correctly.
6) Contact AVERY DENNISON Service.