Axis Communications PS-24 Network Card User Manual


 
PS-24 Mains Adaptor
Connect power to the PS-24
1. Remove the lid of the power supply by removing the 4 screws.
2. Make sure the power switch is set to ‘0’ (off).
Important!
The power switch does not break on both poles at the AC input. The power switch shall only be used to turn
the camera on/off. When the power switch is set to off, high voltage is still present in the AXIS PS-24
mains adaptor. Regard the switch in the building installation as disconnect device.
3. Make sure the voltage selector switch is in the correct position. The setting must
correspond to the input mains voltage i.e.:
set the switch to 115V if you intend to power the unit from a 100-120V mains
voltage line.
set the switch to 230V if you intend to power the unit from a 220-240V mains
voltage line.
4. Remove the outer ring of the cable gland, thread the mains cable (not supplied)
through the outer ring and then through the cable gland.
5. Connect the live/ground wires to AC Input (230VAC and or 115VAC and ).
Replace and tighten the outer ring to secure the cable.
6. Refer to the installation section for your network camera for information on how to
connect the power and alarm inputs/outputs.
7. Check that the cables are securely tightened and that the voltage selector switch is in
the correct position.
Important!
Make sure the power switch is set to ‘0’ (off) until all cables have been connected and
the installation is complete.