4. Replacement in case of a SIM 4/OV DR120 projector
4. REPLACEMENT IN CASE OF A SIM 4/OV DR120
PROJECTOR
4.1 Lamp replacement
CAUTION: Donot touch thecover glass with yourfinge rs. If the lampis touched, finger prints canbe removed
by cleaning the lamp with alcohol.
When to replace the lamp?
The lamp must be replaced at the end of lifetime.
Necessary tools
hexagonal ball driver (5)
Start up
1. Push the cursor key or to highlight Reset Lamp Run Time. (menu 4-1)
2. Press ENTER.
The following warning will be displayed :
Risk of electrical shock. Reset lamp run time is reserved to qualified service personnel. (menu 4-2)
3. Press ENTER
Seemenu4-3.
4. Enter the serial number of the new lamp
5. Press ENTER
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE PROJ. ADDRESS
CHANGE BAUDRATE PC
RESET LAMP RUNTIME
LAMP RUNTIME HISTORY
LIGHT OUTPUT
VOLTAGE DIAGNOSTICS
MORE...
Select with or
then <ENTER>
<EXIT> to return
Menu4-1
WARNING
---------------------
RISK OF
ELECTRICAL SHOCK
---------------------
RESET LAMP RUN TIME
is reserved to
qualified
service personnel
<ENTER> to accept
<EXIT> to return
Menu4-2
Enter serial number:
_______
<ENTER> to accept
<EXIT> to return
Menu 4-3
How to replace the lamp ?
1. Unscrew the hexagonal screw (image 4-1)
2. Open the side door (image 4-2)
3. Disconnect the lamp (image 4-3)
4. Use the long screwdriver to move locking handle downwards to unlock the lamp. (image 4-4)
5. Remove the lamp (image 4-5)
6. Mount the new lamp
7. Move lamp locking handle upwards
8. Close and secure the side door
R5976375 LAMP KIT FOR IQ/SIM4/OV DR 120 PROJECTORS 20/04/2006