20
Peel Time: Determines how long (in seconds) a label will remain in peel
position before moving back to cut position. Ranges from 2 to 9
seconds. Default = 5 sec. NOTE: Peel Time option is not
supported for BradySleeve and PermaSleeve label parts.
Burn Time: Determines the print density on the label. Setting ranges from -5
(lightest) to + 5 (darkest). Default = 0
Term Repeat: Adjusts the terminal block repeat value. Setting ranges from 5
mm to 46 mm. < > > and < ? > keys increase/decrease value by
0.125 mm increments (1 dot). <Shift> + < > > , <Shift> + < ? >
increase/decrease value by 1mm increments (8 dots)
Clean Printer: Performs printer cleaning routine (To be used with the cleaning
card shipped with the unit.).
* Values range from -0.625 mm to +1.375 mm.
** Values range from -1 mm to +1 mm. The < > > and < ? > keys increase/decrease
value by 0.125 mm increments (1 dot).
Barcode
The Barcode menu contains the following user options:
Bar Height: Sets the height of the Code 39 bar code. Setting ranges from 1 to 15
mm. Default = 1. Narrow bar width = 2 dots (.25 mm). Bar Code
Ratio = 2 to 1
Human
Readable:
Determines whether the bar code will be printed together with human
readable text. Toggles between ON and OFF. Font Size = 2 (5 point)
Default = OFF.
Style
The Style menu contains the following user options:
Rotation: Sets the rotation in one of four orientations. 0E, 90E , 180E , 270E.
Default orientation is dependent on the label roll loaded in the unit.
NOTE: Rotation option is not supported for BradySleeve, PermaSleeve,
and pre-printed label parts (defaults to 0E).
H Justify: Sets the horizontal justification of the legend. Options are: Left, Center,
Right. Default setting is determined by the label roll loaded in the unit.
V Justify: Sets the vertical justification of the legend. Options are: Top, Center,
Bottom. Default setting is determined by the label roll loaded in the unit.
Format: Sets the Label Format. Options are: Component, Wire. The Component
label format is designed to print all of the lines of a legend one time before
advancing to the next marker. The Wire format is designed to automatically
repeat the text of a legend down the length of a marker as many times as
possible, considering the number of lines available in the marker. Default =