Brocade Communications Systems 6650 Network Card User Manual


 
Brocade ICX 6650 Administration Guide 273
53-1002600-01
Appendix
A
Syslog messages
Table 57 lists all of the Syslog messages. Note that some of the messages apply only to Layer 3
Switches.
NOTE
This chapter does not list Syslog messages that can be displayed when a debug option is enabled.
The messages are listed by message level, in the following order, then by message type:
Emergencies (none)
Alerts
Critical
Errors
Warnings
Notifications
Informational
Debugging
TABLE 57 Brocade Syslog messages
Message level Message Explanation
Alert <num-modules> modules and 1 power
supply, need more power supply!!
Indicates that the chassis needs more
power supplies to run the modules in the
chassis.
The <num-modules> parameter indicates
the number of modules in the chassis.
Alert Fan <num>, <location>, failed A fan has failed.
The <num> is the fan number.
The <location> describes where the failed
fan is in the chassis.
Alert MAC Authentication failed for
<mac-address> on <portnum>
RADIUS authentication was successful for
the specified <mac-address> on the
specified <portnum>; however, the VLAN
returned in the RADIUS Access-Accept
message did not refer to a valid VLAN or
VLAN ID on the Brocade device. This is
treated as an authentication failure.
Alert MAC Authentication failed for
<mac-address> on <portnum> (Invalid User)
RADIUS authentication failed for the
specified <mac-address> on the specified
<portnum> because the MAC address sent
to the RADIUS server was not found in the
RADIUS server users database.