V - 4
3. DETAILED DESCRIPTION OF
MAINTENANCE-MODE FUNCTIONS
3.1 EEPROM Parameter Initialization
nn Function
The equipment initializes the parameters, user switches, and firmware switches registered in the
EEPROM, to the initial values. Entering the function code 01 initializes all of the EEPROM areas,
but entering 91 does not initialize some areas, as listed below.
Function code
Data item
01 91
Maintenance-mode functions
User switches
Firmware switches
Remote activation code
Activity report
Distinctive ringing patterns
registered
These will be
initialized
Station ID data
Outside line number
Cover page custom comments
Remote access code
FAX forwarding/paging
Personal mailbox password
Telephone function registration
One-touch dialing
Speed dialing
Group dialing
All of these will be
initialized
These will not be
initialized
EEPROM customizing code
(4-digit)
This will not be initialized.
(Note that the first digit of the 4-digit code will be
initialized to "0." If the code is 1001, for example, it will
be initialized to 0001.)
NOTE: If you replace the main PCB with one used for other facsimile equipment, carry out this
procedure and then customize the EEPROM (maintenance-mode function code 74 in Section 3.11).
nn Operating Procedure
(1) Press the 0 and 1 keys (or the 9 and 1 keys according to your need) in this order in the initial
stage of the maintenance mode.
The "PARAMETER INIT" will appear on the LCD.
(2) Upon completion of parameter initialization, the equipment returns to the initial stage of the
maintenance mode.