2006/05/30
APPENDIX D REFERENCE LIST OF MX-2000/4000/5000/7000 SERIES UNIQUE COMMANDS - 6
3.1.2. PJL mailbox protection & bin number setting
Format
@PJL SET/DEFAULT MAILBOXPROTECT=TrayNumber
Parameter
TrayNumber
<HL-2060/2460/7050>
• Lower unit: #1 to 5 from bottom to top
• Lower unit + Upper unit: #1 to 10 from bottom to top
<HL-3260>
#1 to 4 from bottom to top
Default = 0
Explanation
• This command sets the bins with numbers larger than the TrayNumber specified as mailbox use only. They
cannot then be used for either stacker or sorter functions.
• If the bin number is set to 0, the mailbox protection is released, then all bins can be used for stacker and
sorter functions.
• If the bin number is set out of the effective range, this command is ignored.
<HL-2060/2460/7050>
Setting type Effective range
• MX not installed 0
• Lower unit installed
0, 1 ∼ 5
• Lower & upper unit installed
0, 1 ∼ 10
<HL-3260>
Setting type Effective range
• MX not installed 0
• MX installed
0, 1 ∼ 4
• The difference between the SET and DEFAULT selection and the effective period of this setting follow the
PJL specifications.
3.1.3. PJL avoidance of mailbox bin full
Command
@PJL SET/DEFAULT AVOIDMAILBOXFULL=ON/OFF
Parameter
ON/OFF
• OFF: Paper is ejected to the printer face-down output tray when the specified tray is full.
• ON: Paper is not ejected to the printer face-down output tray even when the specified tray is full.
Default = OFF
Explanation
• When paper is ejected into a bin specified by a setting command which limits the bin selection, this
command selects whether to eject automatically paper to the printer face-down output tray or not when the
specified bin is full.
• The difference between the SET and DEFAULT selection and the effective period of this setting follow the
PJL specifications.