Brother PT-E500 Label Maker User Manual


 
EDITING A LABEL
35
Selecting a Labeling Application Type
PUNCH-DOWN BLOCK
Labels printed with this mode can be used to identify a type of electrical connection often
used in telephony. There are up to three lines for each block on a single label and you can
enter three lines for each block. In this mode, you can specify the following items.
Module Width: 8.0" (200 mm), 2.0" (50 mm) - 12.0" (300 mm)
Block Type: 4 Pairs, 2 Pairs, 3 Pairs, 5 Pairs, Blank
Sequence Type: (None), (Horizontal), (Backbone)
Start Value: ---, 1 - 99999
Heat Shrink Tube
When using Heat Shrink Tube, the HEAT-SHRINK TUBE setting screen
will be displayed when any of the labeling application type keys is
pressed.
Label length: Auto, 1.0" (25 mm) - 39.0" (999 mm)
However, the maximum printing length is 19.6" (500 mm) when using
Heat Shrink Tube with a width of 0.23" (5.8 mm) or 0.34" (8.8 mm).
Text: Type in single or multiple lines of data
• When "Blank" is selected in "Block Type", "Sequence Type" is set to None.
When None is selected in "
Sequence Type
", "Start Value" shows "---" and you cannot set
a value. Horizontal or Backbone, however, allows you to set "Start Value" from 1 to 99999.
When using Heat Shrink Tube:
• You cannot print frames.
• Portions of some decorative characters may be cut off when a line is broken.
• The printed characters may be smaller than when using TZe tape.