Cabletron Systems ESX-1320 Switch User Manual


 
Using the LCD
ESX-1320/ESX-1380 Installation Guide 4-11
4.4.3 Alarm Messages
Alarm Messages pertain to events that occur within the ESX regarding
port status. The messages that can be displayed are shown in Table 4-4.
To Display the Messages
There are two ways to gain access and display the Alarm Messages:
From the product name display
Press and hold the DISPLAY button for 3 seconds while the product
name (e.g., CABLETRON ESX-1320) is displayed. When the button
is released, the display steps to the first of the saved Alarm Messages
described in Table 4-4. Thereafter, each time you press the DISPLAY
button, the next message is displayed.
From a Static System Message display
Press and hold the DISPLAY button for 3 seconds while a Static
System Message is displayed. When the button is released, the display
steps to the saved Alarm Messages described in Table 4-4. Thereafter,
each time you press the DISPLAY button, the next saved message is
displayed.
To Exit
There are two ways to exit the Static System Messages:
Automatic 20-second exit
Allowing 20 seconds to elapse after the last DISPLAY button
operation. The display returns to the product name.
Jump to saved System Messages
Press and hold the DISPLAY button for 3 seconds. When the button is
released, the display steps to the saved System Messages described in
Section 4.4.4.
NOTE
Whether you are displaying Static System Messages, Alarm
System Messages, or Saved System Messages, the display
returns to the product name display 20 seconds after the last
operation of the DISPLAY button.