Cabletron Systems SEH-22 Switch User Manual


 
EPIM SPECIFICATIONS
SEH USER’S GUIDE A-5
A.1.4 EPIM-C
The EPIM-C supports thin-net coaxial cabling and is equipped with an
internal Cabletron Systems TMS-3 Transceiver. Use the TERM switch on
the front of the EPIM-C to set the internal 50 ohm terminator. This
eliminates the need to connect the port to a tee-connector and terminator.
Figure A-4 shows the settings for the terminator switch.
Figure A-4. EPIM-C
Connector Type
BNC receptacle, with gold center contact, for use with BNC type tee-
connectors and RG-58 thin-net cable.
Grounding
The BNC port of the Coaxial Interface Module is not internally connected
to earth ground.
EPIM-C
Internal Termination Switch
= On (internally terminated)
= Off (need external termination)
TERM
1490_34
For safety, only one end of a thin-net segment should be
connected to earth ground. Connection to earth ground at
more than one point on the segment may cause dangerous
ground currents.