Casio DT-800RF Barcode Reader User Manual


 
Terminal Setup
Connecting the Cradle
The terminal download requires a serial connection between the terminal and the PC
through a cradle. Connect the serial load cable from a serial port on the PC to the
communications port of the terminal cradle or to a Casio terminal.
In preparation for this download perform the following:
Make sure you have copied the LMWIN utility to any directory on your PC.
Connect the selected serial port on the PC to the cradle with a null modem cable. Use
COM Port 1.
Verify that the cradle is powered on.
If you are using a cradle, configure the cradle baud rate to 115200.
Set the dip switches on the bottom of the cradle. There are ten switches. The up
position of a switch is the on position. The settings for the ten switches are shown
below to set the cradle baud rate to 115200.
Switch 1 2 3 4 5 6 7 8 9 10
Setting On Off Off Off On Off On On On On
When using a cable, the baud rate to select is also 115200.
Terminal Settings
Command Mode Boot
On the portable terminal, power the terminal OFF, then boot the terminal using the key
sequence as shown in the following table.
Command Mode Boot Sequences
Following Power OFF
Terminal Model & Keypad Key Sequence
DT-800RF
Press the FNC and 0 keys,
then press and release the
PWR key,
then release the
FNC and 0 keys.
The System Menu is displayed.
SYSTEM MENU
1. EXECUTE AP
2. SET MODE
3. DATE/TIME
4. TRANSMIT
5. CALIBRATION
6. VERSION
7. SS UTILITY
1. Select
7: SS Utility and then 1: Environment.
2. Enter the IP Address, Netmask, Gateway, Domain, etc.
Supported Equipment Manual March, 2006
2-10