Casio XJH2650 Projector User Manual


 
52
POWER : Amber flashing J
Amber steady
Power has turned off automatically due to internal overheating. Perform
the following steps.
1 Check for any blocking of the projector’s vents, and make sure that
there is sufficient space around the projector. See
Setup Precautions”
(page 11).
2 If there is dust accumulated around the vents, remove it. See
Cleaning
the Projector” (page 50).
If there is no problem with the projector’s vents, confirm that the POWER/
STANDBY indicator is lit amber (without flashing), and then turn power
back on again. If the error occurs again when you turn power back on,
contact your retailer or nearest authorized CASIO Service Center.
LIGHT :
TEMP : –
Message : Internal temperature is too
high. The projector will
turn off.
POWER : Amber flashing J
Red steady
Power has turned off automatically due to a fan problem. Confirm that the
POWER/STANDBY indicator is lit red (without flashing) and that the fan
has stopped. After checking the POWER/STANDBY indicator, disconnect
the power cord from the projector and wait for all of the projector’s
indicators to go out. Next, reconnect the power cord and turn projector
power back on.
If the error occurs again when you turn power back on, contact your
retailer or nearest authorized CASIO Service Center.
LIGHT : Red steady
TEMP : Red steady
Message : There is a problem with
the fan. The projector will
turn off.
POWER : Amber flashing J
Red steady
Power has turned off automatically due to a system problem. After
confirming that the POWER/STANDBY indicator is lit red (without
flashing), disconnect the power cord from the projector and wait for all of
the projector’s indicators to go out. Next, reconnect the power cord and
turn the projector back on.
If the error occurs again when you turn power back on, contact your
retailer or nearest authorized CASIO Service Center.
LIGHT :
TEMP : Red steady
Message : A system problem has
occurred. The projector
will turn off.
POWER : Green steady A system problem has occurred, which may cause problems with some
functions. Turn off the projector, disconnect the power cord from the
projector and wait for all of the projector’s indicators to go out. Next,
reconnect the power cord and turn the projector back on.
If the error occurs again when you turn power back on, contact your
retailer or nearest authorized CASIO Service Center.
Press the [ESC] key to clear the warning message.
LIGHT :
TEMP : –
Message : A system problem has
occurred. Normal
projection is not possible.
POWER : Green steady
LIGHT :
TEMP : –
Message : There is some problem
with the system.
The audio function may
not operate correctly.
POWER : Green steady The USB or LAN connection was terminated because of a problem with
the USB port or LAN port. To use the USB or LAN function, turn off the
projector and then turn it back on again.
If the error occurs again when you turn power back on, contact your
retailer or nearest authorized CASIO Service Center.
Press the [ESC] key to clear the warning message.
LIGHT :
TEMP : –
Message : Some problem occurred
with the USB port or LAN
terminal.
Indicator/Error Message Description and Required Action