Chaparral K5312/K7313 Network Card User Manual


 
G- and K-Series User’s Guide
2-2
To connect to the Fibre Channel port:
1
Be sure the enclosure power is turned off.
2
Connect one end of the Fibre Channel cable to the FC port on the enclosure.
3
Connect the other end of the Fibre Channel cable to a server’s HBA or to an
arbitrated loop hub or fabric switch.
4
Turn power on and begin configuration.
Connecting to the RS-232 Port
You use the RS-232 port to update the firmware, configure, and monitor the
controller using a VT-100/ANSI computer with a terminal emulator.
Refer to your enclosure documentation for information about the correct type of cable
to use. Use a 9-pin straight-through cable. A null modem cable does not work.
Configure the RS-232 port in your terminal emulator software using the following
settings:
!
Baud rate: 9600, 19200, 38400, 57600, or 115200; 115200 best for
downloading firmware upgrades
!
Data Bits: 8
!
Stop Bits: 1
!
Parity: None
!
Flow Control: None or XON/XOFF.
9 Pin Female
D SUB
9 Pin Female
D SUB
22
33
55