Cisco Systems SFS 7000D Switch User Manual


 
6-3
Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide
OL-10853-01
Chapter 6 Hardware Diagnostic Tests
About Diagnostic Tests
Running Chassis Self-Test
The following tests are available to locate and diagnose the chassis:
LED
Standard
Extended
Extended Memory
The example below shows how to run a chassis standard test.
Note The sample text in the steps below shows command output for the Cisco SFS 7000P Server Switch. For
the Cisco SFS 7000D Server Switch, you would see a similar display.
The chassis standard test runs a diagnostic test on the following units in a chassis:
The power supply and fan unit contained in the power supply module
The base card
To perform a chassis standard test, follow these steps:
Step 1 Start the test by entering the diag chassis test standard command and the start command.
SFS-7000P> enable
SFS-7000P# config
SFS-7000P(config)# diag chassis test standard
SFS-7000P(config-diag-chassis)# start
SFS-7000P(config-diag-chassis)#
Step 2 Display the status of the test by entering the show diag chassis command.
SFS-7000P(config-diag-chassis)# exit
SFS-7000P(config)# exit
SFS-7000P# show diag chassis
======================================================================
Diagnostic Tests For Chassis
======================================================================
module-type : chassis
module-number : 1
test : standard
iterations : 1
option : none
action : start
result : success
percentage-completed : 100
result-string : Standard System Test Completed, Final report : Passed=1, Failed=0,
Total=1
SFS-7000P#