Running Power Supply Tests
SFS-7000P# show diag fan
================================================================================
Diagnostic Tests For Fan
================================================================================
module-type : fan
module-number : 1
test : self-test
iterations : 1
action : start
result : success
percentage-completed : 100
result-string : Fan Self Test Completed, Final report : Passed=1, Failed=0, Total=1
SFS-7000P#
Step 4 Display any errors that appear in the result string by entering the show diag fru-error command.
SFS-7000P# show diag fru-error
============================================================
Fru-Error
============================================================
fru-slot fru-error
------------------------------------------------------------
card(1) none
card(2) none
card(7) none
card(8) none
card(9) none
card(10) none
card(11) none
card(12) none
card(13) none
card(14) none
card(15) none
card(17) none
fan(1) none
fan(2) none
Step 5 Reboot the chassis when the self-test is complete.
SFS-7000P# reload
System configuration is modified. Save? [yes(default) | no | filename] y
Proceed with reload? [yes(default) | no] y
Running Power Supply Tests
The following tests are available to locate and diagnose fan modules:
LED Test
Self-Test
Note The sample text in this section shows command output for the Cisco SFS 7000P Server Switch. For the
Cisco SFS 7000D Server Switch, you would see a similar display.