Cisco Systems SFS 7000D Switch User Manual


 
A-1
Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide
OL-10853-01
APPENDIX
A
Specifications and Compliance Certifications
This appendix describes the Cisco SFS 7000P and SFS 7000D Server Switches specifications and
compliance certifications.
Chassis and Management Interface
Table A-1 lists the general specifications for the Cisco SFS 7000P and SFS 7000D Server Switches.
Table A-1 Cisco SFS 7000P and SFS 7000D Server Switches and Management General Specifications
Item Specification
Operating temperature 0 to 45°C (32°F to 113°F)—Cisco SFS 7000P Server Switch
0 to 40°C (32°F to 104°F)—Cisco SFS 7000D Server Switch
Nonoperating temperature -40 to 70°C (-40 to 158°F)
Operating temperature gradient 20°C (68°F) max. per 60 min
Operating altitude 0 to 3,048 m (0 to 10,000 ft)
Nonoperating altitude 0 to 12,192 m (0 to 40,000 ft)
Operating humidity: 8 to 80% non-condensing
Nonoperating humidity: 5 to 90% RH at 65°C (149°F) for 24 hours, non-condensing
Operating humidity gradient 10% maximum per 60 min
Operating shock 5 G max., 11 ms half-sine wave, 10 G max. 5 ms half-sine wave
Nonoperating shock 10 G max., 11 ms half-sine wave
Operating vibration, sinusoidal 0.25 G max., 3-200 Hz 15 min
Nonoperating vibration, sinusoidal 0.50 G max., 3-200 Hz 15 min
Nonoperating vibration, random 2.09 Grms, 3-axis, bottom/top, left/right, front/back
Max. operating inclination 15 degree
Physical Characteristics
Dimensions 1 RU, fits in standard 19-in. (48.26 cm) rack
Length 21 in. (53.34 cm)
Weight Maximum weight is 22 lb (10 kg)