CBM-910 User’s Manual
CITIZEN
26
(2) SI / SO and US / RS Commands
SI / SO codes function in the same manner as US / RS as long as 8-bit data are assigned (serial communication data
bit length), which, however, are divided, under 7-bit assignment, into SI (20H~7FH characters) print assignment and
SO (A0H~FFH characters) print assignment functions.
1. Standard letter assignment (SI / US) command:
With SI (0FH)/ US (1FH) codes input, lateral enlargement is cancelled and the data following are printed in standard
letters.
This command can cancel only lateral enlargement, which dose not apply to x 4 enlargement.
2. Laterally enlarged letter assignment (SO / RS) command:
With SO (0EH)/RS (1EH) codes input in any columns, the data following are printed in prints enlarged double in
width. With line feeding or SI / SR code input, this command is cancelled.
Although standard and enlarged letters can be mixed within one line, automatic (buffer-full) printing takes place
when the number of columns reaches 24 (or 40) counted in standard letters.
[Receiving Data]
SO 1 2 3 4 5 6 7 8 6 0 CR
SO 123 SI ABCD CR
SO 123 SI ABC SO 12 CR
A SI 1 2 3 4 5 6 7 8 9 0 1 B
[Results of Printing]
1234567890
123
ABCD
123
ABC
12
Mixed printing
A
12345678901
B
Although the last letter has been assigned to lateral enlargement, it is
printed in standard letter as it is in 24th columns. (For 40-column
mechanism this is applied to 40th columns.)