CyberPower Systems UP425 Personal Computer User Manual


 
DEFINITIONS FOR ILLUMINATED LED INDICATORS
Power
On
Using
Battery
Wiring
Fault
Circuit
Breaker
Alarm
Condition
On Off Off Set Off
Normal
Off On On/Off Set
Two
Beeps
Utility Failure- The UPS is providing battery power
to the Battery-Power Supplied outlets.
Off On On/Off Set
Rapid
Beeps
Utility Failure- The UPS is providing battery
power. The rapid beeps indicate the battery will
run out of charge within a few minutes.
Off On Off Up
Two
beeps
or
rapid
beeps
Overload- Occurs in the Full-time Surge
Protection Outlets. Turn the UPS off and unplug
at least one piece of equipment from the UPS.
Wait 5 seconds, reset the circuit breaker and turn
the UPS on.
Off
On/Off On/Off Set
Long
Beep
Overload- Occurs in the Battery-power Supplied
Outlets. Turn the UPS off and unplug at least one
piece of equipment from the UPS. Wait 5
seconds, reset the circuit breaker and turn the
UPS on.
On/Off On/Off On Set/Up None
Electrical Wiring Fault- This indicates a wiring a
problem such as a bad ground, missed ground or
reversed wiring within the AC outlet. User is
advised to disconnect all electrical equipment
from the outlet and have the outlet checked by an
electrician.