Cyclades PC400 Modem User Manual


 
23Chapter 4 Board and System Configuration
Parameter Description Value for T1
line
Value for E1
line
unit_name Name used to identify the board. PC400 PC400
prompt Can be changed to identify which board is being
accessed.
Select option
==>
Select option
==>
escape_char 0x1b is the <ESC> key. 0x1b 0x1b
shortcut_char 0x0 turns this feature off. 0x0 0x0
username Login name for administrator. super super
password Password for administrator supc supc
syslog Enables syslog messages indicated. enabled
line|debug|user|s
ystem|modem
info
enabled
line|debug|user|s
ystem|modem
info
interf1_begin First interface parameters
interf_type Indicates line time t1 e1
clock_mode Normally slave. slave slave
line_code There are two options each for T1 and E1 lines. Ask
the service provider.
b8zs hdb3
frame_mode There are several data framing options for both T1
and E1.
esf crc4
line_build_out Applies only to T1 lines. Ask the service provider. 0db
signaling_mode Can be pri (ISDN), cas or none. cas cas
FIGURE 4.8 RAS DIAL-IN APPLICATION PARAMETERS