Cyclades PC400 Modem User Manual


 
29Chapter 5 Troubleshooting
Cyclades-PC400 Installation Manual
Hardware Test
A menu-driven hardware test called pc400hwtest is included with the Cyclades-PC400 driver. It is executed by
typing pc400hwtest at the command line. Note that the PC400 should not be tested while in use as the test will
inactivate all ports. First, RAM integrity is checked:
[root@cyclades common]# ./pc400hwtest
Please wait while program is examining the hardware
BOARD[1] RAM TEST ED000000, PCI ED926000 OK !
Press [enter] to continue.
Application Checking Firmware Integrity (CRC) ... OK
Then press the <ENTER> key to bring up the main screen, shown below:
PC400HWTest/Linux
Revision 2.0.0 (2001/12/12)
1. Test Asynchronous Ports
2. Test T1 Channelized Ports
3. Test E1 DSP Ports
4. Quit
Select option ==>