SOFTWARE CONFIGURATION
31
3
3.4 CONFIGURATION
Once connected to Matrix-1000 as described in par. 3.3, you can modify the
configuration parameters as follows:
1. Press the Calibration Tool button from the Main Menu. Matrix-1000™ will
download its permanent memory configuration parameters with the default
values (if it is the first time) to VisiSet™. The Calibration Tool window will be
displayed together with the Parameter Setup window working in Interactive
Mode (see par. 3.4.1 and par. 3.4.2).
2. Edit the Matrix-1000 configuration parameters according to your application
requirements.
3. Use the Calibration Tool to fine tune the reading performance. See par. 3.4.2.
4. Close the Calibration Tool window and disable the Interactive Mode by pressing
the interactive button.
5. Save the new configuration to the reader permanent memory by pressing the
Send button.
6. Close the Parameter Setup window and press Disconnect on the VisiSet™
menu bar (see Figure 28) or launch Run Mode from the VisiSet™ Main menu.
Disconnect exits closing communication between Matrix-1000 and
VisiSet™, and causes Matrix-1000 to enter Run Mode. The disconnected
reader serial port is now available for other purpose.
Run command does not close communication between Matrix-1000 and
VisiSet™, and causes Matrix-1000 to enter Run Mode. In this case the
reader output messages are displayed on the VisiSet™ terminal and the
statistics are displayed in the Statistics window (Statistics enabled).