Data Editing
4-4 PowerScan
®
7000 2D
Example: Add a Suffix to a specific symbology
To send a CR (carriage return)Suffix for UPC only:
Step 1. Scan Add Suffix.
Step 2. Determine the 2 digit hex value from the Symbology Chart (included
in ASCII Conversion Chart (Code Page 1252) on page A-4) for UPC.
Step 3. Scan 6, 3 from the Programming Chart on page B-5 of this manual.
Step 4. Determine the hex value from the ASCII Conversion Chart (Code
Page 1252) on page A-4, for the CR (carriage return).
Step 5. Scan 0, D from the Programming Chart on page B-5 of this manual.
Step 6. Scan Save, or scan Discard to exit without saving.
To Clear One or All Prefixes or Suffixes:
You can clear a single prefix or suffix, or clear all prefixes/suffixes for a
symbology. When you Clear One Prefix (Suffix), the specific character
you select is deleted from the symbology you want. When you Clear All
Prefixes (Suffixes), all the prefixes or suffixes for a symbology are deleted.
Step 1. Scan the Clear One Prefix or Clear One Suffix symbol.
Step 2. Determine the 2 digit Hex value from the Symbology Chart (included
in ASCII Conversion Chart (Code Page 1252) on page A-4) for the
symbology from which you want to clear the prefix or suffix.
Step 3. Scan the 2 digit hex value from the Programming Chart on page B-5
of this manual or scan 9, 9 for all symbologies.
Your change is automatically saved.
To Add a Carriage Return Suffix to all Sym-
bologies
Scan the following bar code if you wish to add a carriage return suffix to
all symbologies at once. This action first clears all current suffixes, then
programs a carriage return suffix for all symbologies.
Add CR Suffix
All Symbologies