Linear Symbologies
Product Reference Guide 6-25
EAN/JAN-13 Addenda Required
When Addenda Required is set to on, the imager will only read EAN/
JAN-13 bar codes that have addenda. Default = Not Required.
EAN/JAN-13 Addenda Separator
When this feature is on, there is a space between the data from the bar
code and the data from the addenda. When turned off, there is no space.
Default = On.
ISBN Translate
This selection causes EAN-13 Bookland symbols to be translated into
their equivalent ISBN number format. Default = Off.
NOTE
If you want to enable or disable EAN13 with
Extended Coupon Code, refer to
UPC-A/EAN-
13 with Extended Coupon Code on page 6-21
.
* Not Required
Required
Off
* On
* Off
On