Datalogic Scanning 7000 Scanner User Manual


 
Data Editing
4-6 PowerScan
®
7000 2D
Intercharacter, Interfunction, and
Intermessage Delays
Some terminals drop information (characters) if data comes through too
quickly. Intercharacter, interfunction, and intermessage delays slow the
transmission of data, increasing data integrity.
Each delay is composed of a 5 millisecond step. You can program up to
99 steps (of 5 ms each) for a range of 0-495 ms.
Intercharacter Delay
An intercharacter delay of up to 495 milliseconds may be placed between
the transmission of each character of scanned data. Scan the Intercharac-
ter Delay bar code below, then scan the number of milliseconds and the
SAVE bar code using the
Programming Chart on page B-5 of this manual.
To remove this delay, scan the Intercharacter Delay bar code, then set the
number of steps to 0. Scan the SAVE bar code using the
Programming
Chart on page B-5
of this manual.
NOTE
Intercharacter delays are not supported in USB
serial emulation.
1 2345
Intercharacter Delay
Prefix Scanned Data Suffix
Intercharacter Delay