2.6 TYPICAL LAYOUTS
The following typical layouts refer to system hardware configurations. Dotted
lines in the figures refer to optional hardware configurations within the
particular layout.
These layouts also require the correct setup of the software configuration
parameters. Complete software configuration procedures can be found in the
Guide To Rapid Configuration
in the WinHost Help On Line.
2.6.1 Point-to-Point
In this layout the data is transmitted to the Host on the main serial interface.
Host Mode programming can be accomplished either through the main
interface or the auxiliary interface.
In Local Echo communication mode, data is transmitted on the RS232
auxiliary interface independently from the main interface selection.
When On-Line Operating mode is used, the scanner is activated by an
External Trigger (photoelectric sensor) when the object enters its reading
zone.
DS4300
2
3
Terminal
1
Host
Auxiliary serial interface (Local Echo)
2
External Trigger (for On-Line mode)
3
Main serial interface
1
Figure 2.28 - Point-to-Point layout