READING FEATURES
4
For DX scanners the zero coordinate references are located on the scanner.
PackTrack™ Coordinate Reference Point
where x, y, z = 0
Figure 67 – DX6400 Coordinate Reference Point
4.2.1 PackTrack™ Calibration for DX6400
The DX6400 scanner calibration is already made at the factory and it is not
recommended to overwrite it. By means of the Genius™ software tool SPY, the user can
set the Direction and PS Offset parameters.
Select the “SPY” option from the Tools menu or click on the related icon on the Genius™
toolbar to open the following dialog box:
Note: When selecting a slave scanner through the Master, click on the slave in the Devices
window, then click the SPY icon.
SPY ICON
Figure 68 – Opening the Spy Window
59