4.2.2 Overwriting PackTrack™ Calibration for DX6400
Only necessary for special circumstances, it is possible to overwrite the factory scanner
calibration by clicking on the “Calibrate DX” button shown in the figure above.
The PackTrack™ Calibration window will expand and appear as shown in the following
figure:
Position 3
Position 2
Position 1
Position 3
Position 2
Position 1
Figure 71 – Performing the PackTrack™ Calibration
To overwrite the factory scanner calibration, follow the procedure below for Leg 1:
1. Place the code at the desired position on the laser beam (Position 1).
2. Measure the X, Y and Z coordinates relative to the center of the code and enter them
into the corresponding edit boxes.
3. Press the Calibrate button for Position 1 to start the calibration.
4. Repeat the same procedure for Position 2 and Position 3.
5. Press the “Validate Calibration” button to validate the calibration settings.
6. Repeat the whole procedure for Leg 2.
Before closing the dialog box, press the Run Test button to test the calibration results and
efficiency.