Datalogic Scanning PD7100 Barcode Reader User Manual


 
Symbologies
154 PowerScan
®
PD7100 Corded
GS1 DataBar Expanded — cont.
GS1 DataBar Expanded Set Length 2
This feature specifies one of the barcode lengths for GS1 DataBar Expanded Length
Control
. Length 2 is the maximum label length if in Variable Length Mode, or the sec-
ond fixed length if in
Fixed Length Mode. Length includes the barcode’s data characters
only.
The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 74). Pad the number with lead-
ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
ming Mode.
3. Scan the barcode: SELECT GS1 DATABAR EXPANDED LENGTH 2 SET-
TING.
4. Scan the appropriate two digits from the keypad in
Appendix E, Keypad, that rep-
resent the length setting which was determined in the steps above. You will hear a
two-beep indication after the last character.
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See Table 20 for some examples of how to set this feature.
Table 20. GS1 DataBar Expanded Length 2 Setting Examples
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP ACTION EXAMPLES
1 Desired Setting
00 (ignore second
length)
07 Characters 52 Characters 74 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT GS1 DATABAR EXPANDED LENGTH 2 SETTING
4
Scan Two Characters From
Appendix E, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘5’ and ‘2’ ‘7’ and ‘4’
5 Scan ENTER/EXIT PROGRAMMING MODE