Symbologies
196 PowerScan
®
PD7100 Corded
Interleaved 2 of 5 (I 2 of 5) — cont.
2 of 5 Decoding Level
Decoding Levels are used to configure a barcode symbology decoder to be very aggressive
to very conservative depending on a particular customer’s needs.
• Choosing Level 1 results in a very conservative decoder at the expense of not being
able to read poorly printed or damaged labels.
• Choosing Level 5 results in a very aggressive decoder. This aggressive behavior
allows decoding of poorly printed and damaged labels at the expense of increasing
the likelihood of decoding errors.
• Choosing Level 3, which is the default setting, allows the majority of product
labels to be decoded.
There are many factors that determine when to change the decoding level for a particular
symbology. These factors include spots, voids, non-uniform bar/space widths, damaged
labels, etc. that may be experienced in some barcode labels. If there are many hard to read
or damaged labels that cannot be decoded using a conservative setting, increase the de-
coding level to be more aggressive. If the majority of labels are very good quality labels,
or there is a need to decrease the possibility of a decoder error, lower the decoding level
to a more conservative level.
NOTE
This configuration item applies to Interleaved 2 of 5, Datalogic 2 of 5 and
Standard 2 of 5.